This paper presents the general guidelines for the determination of the susceptibility of electrostatic components and equipment to electrostatic discharge, following a system level test that replicates an electrostatically charged person, this discharge to a system in an end user environment , this method is called the Human Body Model. The purpose of the system-level test is to ensure that the finished products can survive normal operation and it is generally assumed that the user of the product will not take any precautions to reduce possible electrostatic discharge and its effects. Data were taken from the most commonly used standards for describing test procedures, test levels and methods or ways of classifying them. It was concluded that the determination of the susceptibility to electrostatic discharges allows to provide data for an adequate possession of the manufacture, manipulation and use of products, a correct choice of them according to their destination and provides the data necessary for the implementation of protections before electrostatic discharge.
Downloads
Article Details
Section
References
ESD Fundamentals (2013)[Online 22/05/17]. Available: www.esda.org . 2013.
I. E. Commission, International standard (1999) IEC 61000-4-2: electromagnetic compatibility (EMC). Testing and measurement techniques – electros .1999.
Koki Narita; Mototsugu Okushima. “Low Clamping Voltage Protection for Improvements of Powered ESD Robustness”. 2018 40th Electrical Overstress/Electrostatic Discharge Symposium (EOS/ESD). IEEE Conferences, pp. 1-8. sept/oct 2018.
Fernández, J. C. (2016) Clase 2 interferencia conducida. Compatibilidad Electromagnética Universidad Nacional de Misiones – 2016.
Fernández, J. C. “Modelos estáticos y circuitales” en Ingeniería electromagnética. EUDEBA-2013-Biblioteca de Ingeniería. ISBN 9789502320946. 2013
ESDA. ESD fundamentals. (2013) [Online13/8/16]. Available: https://www.esda.org/about-esd/esd- fundamentals/ . 2013.
Ott, H. W. (2011) Electromagnetic Compatibility Engineering. Wiley, 2011.
E. E. A.(2001) Staff, Sensitivity Testing - Human Body Model (HBM) Component Level: Ansi/esd Stm5.1- 1998. . EOS/ESD Association, Incorporated, 2001.
Yang Xiao ; Ann Concannon; Rajkumar Sankaralingam. “HBM failures induced by ESD cell turn-off and circuit interaction with ESD protection”. 2015 37th Electrical Overstress/Electrostatic Discharge Symposium (EOS/ESD). IEEE Conferences, pp. 1-7. sept/oct 2015.
N. S. S. C. (1994), W. DC. Military Handbook: Electrostatic Discharge Control Handbook for Protection of Electrical and Electronic Parts, Assemblies and Equipment (Excluding Electrically Initiated Explosive Devices (Metric). Defense Technical Information Center, 1994.
Junsik Park; Jongsung Lee; Cheolgu Jo; Byongsu Seol ; Jingook Kim. “A Proto-type ESD Generator for System Immunity Test of Wearable Devices”. 2018 40th Electrical Overstress/Electrostatic Discharge Symposium (EOS/ESD). IEEE Conferences, pp. 1-6. sept/oct 2018.
EOS/ESD Association (2013) Incorporated, ANSI/ESD S8. 1-2012 ESD Association Standard for the Protection of Electrostatic Discharge Susceptible Items - Symbols - ESD Awareness. EOS/ESD Association, Incorporated, 2013.
EOS/ESD (2014).Association- Incorporated, ANSI/ESD S6. 1-2014 - ESD Association Draft Standard for the Protection of Electrostatic Discharge Susceptible Items - Grounding. EOS/ESD Association, Incorporated, 2014.